Factories Act, 1934
Factories Act, 1934 — section 33A
33A. Hoists and lifts..—_(1) In every factory
(a)every hoist and lift shall be
(i)of good mechanical construction, sound material and adequate strength ;
(ii)properly maintained, and shall be thoroughly examined by a competent person authorised by the Chief Inspector in this behalf at least once in every period of six months, and a register shall be kept containing the prescribed particulars of every such examination of which a copy shall be forwarded to the Chief Inspector ;
(b)every hoistway and liftway shall be sufficiently protected by an enclosure fitted with gates, and the hoist or lift and every such enclosure shall be so constructed as to prevent any person or thing from being trapped between any part of the hoist or lift and any fixed structure or moving part ;
(c)the maximum safe working load shall be plainly marked on every hoist or lift, and no load greater than such load shall be carried thereon ;
(d)the cage of every hoist or lift used for carrying persons shall be fitted with a gate on each side from which access is afforded to a landing ;
(e)every gate referred to in clause (b) or clause (d) shall be fitted with interlocking or other efficient device to secure that the gate cannot be opened except when the cage is at the landing and that the cage cannot be moved unless the gate is closed.
(2)The following additional requirements shall apply to hoists and lifts used for carrying persons and installed or reconstructed in a factory after the commencement of the Labour Laws (Amendment) 1972, namely :
(a)Where the cage is supported by rope or chain there shall be at least two ropes or chains separately connected with the cage and balance weight, and each rope or chain with its attachments shall be capable of carrying the whole weight of the cage together with its maximum load ;
(b)efficient devices shall be provided and maintained capable of supporting the cage together with its maximum load in the event of breakage of the ropes, chains or attachments ;
(c)an efficient automatic device shall be provided and maintained to prevent the cage from over-running.
(3)The Chief Inspector may permit the continued use of a hoist or lift installed in a factory before the commencement of this Ordinance which does not fully comply with the provisions of sub section (1) upon such conditions for ensuring safety as he may think fit to impose.
(4)The Provincial Government may, if, in respect of class or description of hoist or lift, it is of opinion that it would unreasonable to enforce any requirement of sub-sections (1) and (2), by order direct that such requirements shall not apply to such class or description of hoist or lift.
This is the text of the provision as enacted. It is legal information, not legal advice, and it cannot account for the facts of your own matter. For advice on your situation, consult a verified advocate.